Medcoa Biotechnology (Shanghai) Co., Ltd. logo
CVNMPA Class III · Blood contact

Changtu™ CV Series

Hydrophilic coating for blood-contacting devices

In short

Changtu™ CV is a UV-cured hydrophilic coating for polymer substrates used in blood-contacting Class III devices. It is available in single- or dual-layer structures and is typically specified for cardiovascular, peripheral and neurovascular interventions.

Changtu™ CV hydrophilic coating applied to a cardiovascular interventional catheter: wetted guidewire surface

Formulation & Process

Series code
CV
Form
Liquid, ready to use
Cure
UV-cured (intensity ≥30 mW/cm²)
Structure
Single-layer or dual-layer
Shelf life
3 years, room temperature, protected from light
Substrates
Polymer substrates

Published Performance Data

PropertyValue
Coefficient of frictionAs low as 0.02–0.03[1]
Abrasion resistanceNo delamination after 25 or more friction cycles[2]
Particulate releaseMeets Chinese Pharmacopoeia and USP-788 requirements[3]
  1. [1] Company-published figure. The method refers to the friction test of YY/T 1898-2024 (test method for the durability of hydrophilic coatings on intravascular catheters and guidewires), but the specific conditions the standard requires — normal clamping force, reciprocating speed, medium and temperature — are not stated for this figure. Not valid for cross-product or cross-laboratory comparison. For registration files or supplier benchmarking, request a report with full test conditions.
  2. [2] Internal evaluation criterion. The cycle count exceeds the minimum of 10 recommended in YY/T 1898-2024. Test method, stroke length, counterface and pass criteria are to be specified.
  3. [3] Assessed per Chinese Pharmacopoeia (2020, Vol. IV) method 0903 for insoluble particulate matter and per USP-788. Test medium, immersion conditions and acceptance thresholds are to be specified. USP-788 was originally written for injections and infusion preparations — its applicability to intravascular catheters must be confirmed against the specific device standard.

Substrates

  • TPU
  • PA (nylon)
  • PVC
  • Pebax

Typical Applications

  • Cardiovascular intervention
  • Peripheral intervention
  • Neurovascular intervention

Design Intent

  • Low particulate release for demanding vascular applications

Common Questions

Which devices is Changtu™ CV intended for?
Changtu™ CV is intended for blood-contacting Class III devices built on polymer substrates, typically cardiovascular, peripheral and neurovascular interventional devices. These devices usually carry strict requirements on particulate release, coating durability and lubricity retention, so selection should be evaluated against the specific device construction and clinical dwell time.
Under what conditions was the 0.02–0.03 coefficient of friction measured?
This is a company-published figure. The method refers to the friction test of YY/T 1898-2024, which specifies reference ranges for normal clamping force, reciprocating speed, medium, temperature and cycle count. Coating friction is highly sensitive to these parameters, so a value without stated conditions cannot be compared across products or laboratories. Contact us for a report with full test conditions if you need it for a registration file or supplier benchmarking.
How do I choose between polymer and metal substrates?
Substrate type is the first selection criterion. Polymer substrates such as TPU, PA, PVC and Pebax use Changtu™ CV or Youtu™ UC, depending on whether the device contacts blood. Metal substrates such as stainless steel and nitinol should use Meitu™ MT, whose coating system is optimised for adhesion to metal surfaces.
Should I specify a single-layer or dual-layer structure?
Single-layer structures involve fewer process steps and suit simpler device constructions. Dual-layer structures are typically used where primer adhesion and topcoat lubricity need to be controlled separately. The choice should be settled against substrate, device construction and target performance, using test results from actual samples.
Do you support customers' regulatory submissions?
Yes. We provide material chemical composition and safety data, biological evaluation data performed in accordance with the ISO 10993 series, and a TÜV SÜD biological evaluation report for hydrophilic-coated urinary catheters (Report No. 748267139301C/CN), covering the material documentation required in a customer's submission. NMPA Master File registration is not yet completed; we will inform customers once it is. If your submission timeline is fixed, contact us directly to confirm the document list and delivery schedule.

Technical Directions

Functional directions that can be layered onto the series.

Request a sample of Changtu™ CV Series

Send the substrate grade, device construction and target performance. We will confirm the grade and process route and arrange samples where appropriate.

Contact Mr. Shi