Glossary
In short
Standard terminology for hydrophilic coating technology, with the definition and the usage constraint of each term. 7 entries are listed, covering coating types, friction and lubricity measurement, and regulatory paths.
Because Chinese standards (YY/T, GB/T) use terminology that does not always map directly onto English industry usage, the closest English equivalents are given as aliases. This is intended to help procurement, regulatory and technical teams work from one vocabulary.
- Hydrophilic coating
- A polymer coating applied to a medical device surface that takes up water and swells into a hydrated layer, lowering the coefficient of friction at the surface.
- We use 'hydrophilic coating' throughout rather than subjective terms such as 'ultra-slippery'. Where lubricity is described, the coefficient of friction is given together with its test conditions.
- One-component hydrophilic coating
- A hydrophilic coating system supplied in a single package and used as delivered, with no on-site mixing of components.
- This term describes the packaging and supply form only — single container, ready to use, no on-site mixing. It does not indicate higher or lower performance.
- Antibacterial hydrophilic coating
- A hydrophilic coating system incorporating an antibacterial component with activity against specified microorganisms.
- This is a quantified material surface property. We present the test standard, the test strains and the measured inhibition data, and make no statement in the medical or clinical domain.
- Coefficient of friction
- A quantitative measure of surface lubricity, expressed as the ratio of friction force to normal force. A lower value indicates a more lubricious surface.
- Whenever a coefficient of friction is stated, the test conditions — load, speed, counterface and medium — are stated with it. Values obtained under different conditions are not directly comparable.
- Lubricity retention
- The ability of a coating to remain in a hydrated, lubricious state after wetting, which governs how long lubricity persists during use.
- Where a lubricity retention value is given, the test method and environmental conditions (temperature, humidity, duration) are stated with it. Values obtained under different conditions are not directly comparable.
- NMPA Master File
- A technical document registered with the Chinese regulator by a raw material or component supplier, for reference by a device registration applicant in a medical device submission.
- Master File registration is a documentation act and does not mean a product has obtained a registration certificate. Medcoa has not yet completed this registration, so this site describes the system only and makes no capability commitment.
- Biological evaluation
- Evaluation of the biocompatibility of a medical device and its materials in accordance with the ISO 10993 series.
- Where a biological evaluation report is cited, the report number and the scope of its conclusions are stated. Partial test conclusions are not extrapolated into overall safety statements. The final endpoint set is determined by the device registration applicant based on contact nature and duration.
Also: lubricious coating, hydrophilic lubricious coating
Also: ready-to-use coating, 1K coating
Also: antimicrobial coating
Also: CoF, μ
Also: water retention, lubricity duration
Also: Master File, 医疗器械主文档
Also: biocompatibility evaluation, ISO 10993
Common Questions
Why terms are defined this way, and what some of them do not mean.
- Why does Medcoa publish a terminology list?
- Technical terms are used inconsistently across the industry, and inconsistencies make it difficult to confirm whether two documents describe the same thing. Publishing the standard terms, their definitions and their usage constraints lets procurement teams, regulatory agents and technical teams work from the same vocabulary.
- Does 'one-component' mean the coating performs better?
- No. One-component describes the supply form — a single package, ready to use, no on-site mixing. It says nothing about performance. Actual coating performance depends on formulation design, substrate and cure process.
- Why are coefficients of friction always given with test conditions?
- Coefficient of friction is not an intrinsic material constant. It changes with normal force, speed, counterface material, medium and temperature. A value without its conditions can be neither reproduced nor compared across products or laboratories, so we state them together.
- What is the difference between a Master File and a registration certificate?
- A Master File registers material technical documentation with the regulator; a registration certificate is granted to a specific medical device after a successful product submission. Master File registration does not mean any product has been approved. Medcoa has not yet completed Master File registration.
