Meitu™ MT is a hydrophilic coating for metal-substrate devices, optimised for adhesion to stainless steel and nitinol. It uses a dual- or triple-layer system combining thermal and UV curing, and is typically specified for cardiovascular, peripheral and neurovascular interventions.

Formulation & Process
- Series code
- MT
- Form
- Liquid, ready to use
- Cure
- Thermal + UV-cured (intensity ≥30 mW/cm²)
- Structure
- Dual-layer or triple-layer
- Shelf life
- 3 years, room temperature, protected from light
- Substrates
- Metal substrates
Published Performance Data
| Property | Value |
|---|---|
| Adhesion | Optimised for stainless steel and nitinol surfaces[1] |
| Coating durability | Dual/triple-layer system focused on interfacial bond strength[2] |
- [1] The adhesion evaluation method (cross-hatch, tensile pull-off, or visual assessment after friction cycling) and pass criteria are to be specified.
- [2] This is a structural design description. Actual performance under friction and deformation should be evaluated by the friction test of YY/T 1898-2024 or a customer-agreed method; pass criteria are to be specified.
Substrates
- Stainless steel
- Nitinol
- Other metal substrates
Typical Applications
- Cardiovascular intervention
- Peripheral intervention
- Neurovascular intervention
Design Intent
- Interfacial bonding engineered for metal substrates, with a choice of coating layers
Common Questions
- Why do metal substrates need a dedicated coating series?
- Metal surfaces are high-energy and chemically inert, so they form stable chemical bonds with organic coatings only with difficulty — adhesion is a harder problem than on polymer substrates. Meitu™ MT addresses the interface with a purpose-designed primer system and uses thermal plus UV curing to combine adhesion with production efficiency.
- When should a dual-layer versus a triple-layer structure be used?
- More layers allow better control of interfacial bonding and property gradients, but add process steps and quality control points. Devices with complex construction and large deformation — a guidewire that must bend sharply, for example — tend to favour multi-layer systems. The choice should be settled by testing samples under simulated use conditions.
- What does thermal plus UV curing require on a production line?
- The process requires both a heating step and a UV exposure step, so it adds one process stage compared with pure UV curing. During selection we confirm your existing line conditions with you and assess whether the process flow or equipment needs adjustment.
- How should coating durability be verified on nitinol devices?
- Nitinol devices often undergo significant deformation in use, and a single static test does not capture the real risk. We recommend combining friction cycling, simulated vessel-path tracking and post-deformation visual inspection. The verification plan should be settled against the device design features and clinical use.
- Do you provide submission support documents for metal-substrate devices?
- Yes. We provide material chemical composition and safety data, biological evaluation data performed in accordance with the ISO 10993 series, and a TÜV SÜD biological evaluation report for hydrophilic-coated urinary catheters (Report No. 748267139301C/CN), covering the material documentation required in a customer's submission. NMPA Master File registration is not yet completed; contact us to confirm the document list and delivery schedule.